Results 1 - 20 de 34
Filter
1.
Acta odontol. latinoam ; 36(1): 40-46, Apr. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447074

ABSTRACT

ABSTRACT During ceramic veneer luting, resin cement polymerization is performed with interposition of the dental ceramic. Aim: To evaluate how and how much the photoactivation time affects the Vickers hardness of resin-based cements with interposed ceramic. Materials and Method: A total 24 specimens H mm in diameter and 1 mm thick were made from Paracore White Coltene (PC), Densell Resin Duo Cement (DC), 3MRelyX Veneer (RX) and Coltene Fill Up! (FU), interposing VitablockMarkII (Vita Zahnfabrik) feldspathic ceramic 0.6 mm thick during photoactivation. The materials were polymerized using 100% and 25% of the times indicated by the manufacturers with a Coltolux LED ((Coltene) light with intensity 1200 mW/cm2. Each polymerization time group consisted of three specimens of each material, which were stored dry in darkness at 37 °C for 7 days. Three Vickers microhardness measurements were made on the top and bottom surfaces of each specimen using a Vickers Future Tech FM300 microhardness tester (300 g, 5 s). The values were averaged, and the bottom/top ratios calculated. Results were analyzed by ANOVA. (p<0.05) complemented with multiple comparisons using Tukey's test (p<0.05). Results: Different photoactivation times were found to have a significant effect on hardness values of the cements evaluated, with significant differences between some of the cements. No statistically significant difference was found for the effect of photoactivation time on bottom/top microhardness ratio in those materials. Conclusions: Under the experimental conditions employed, it can be concluded that photopolymerization for shorter times and the interposition of restorative material significantly affectpolymerization quality as evaluated by microhardness, but the bottom/top ratio was unaffected by differences in polymerization time.


RESUMEN Durante la fijación de una carilla cerámica, la polimerización del cemento a base de resinas se realiza con la interposición de la cerámica dental. Objetivo: evaluar en qué forma y magnitud afecta el tiempo de fotoactivación en la dureza Vickers de los cementos a base de resinas con la cerámica interpuesta. Materiales y Método: se confeccionaron 24 probetas de 11 mm de diámetro y 1 mm de espesor con: Paracore White Coltene (PC), Resin Duo Cement de Densell (DC), RelyX Veneer de 3M (RX) y Fill Up! De Coltene (FU) interponiendo 0,6 mm de espesor de cerámica feldespática Vitablock Mark II (Vita Zahnfabrik) durante la fotoactivación. Se polimerizó utilizando el 100% y el 25% del tiempo indicado por el fabricante con lámpara Coltolux LED ((Coltene) con 1200 mW/cm2 de intensidad. Cada grupo quedó conformado con tres probetas de cada material que se almacenaron a oscuras y en seco a 37 °C durante 7 días. Se registraron tres mediciones de microdureza Vickers de las superficies top y bottom de cada probeta con un microdurómetro Vickers Future Tech FM300 (300 g, 5 s) y se calculó su promedio, así como la relación entre los valores registrados en cada una de sus caras. Los resultados fueron analizados por medio de la prueba de ANOVA. (p<0.05). complementada con comparaciones múltiples por medio de la prueba de Tukey (p<0.05). Resultados: se encontró un efecto significativo de la modificación del tiempo de fotoactivación en los valores de dureza de los cementos evaluados con diferencias significativas entre algunos de ellos. Simultáneamente no se encontró significación estadística en el efecto de ese factor sobre la relación microdureza bottom/top registrada en esos materiales. Conclusiones: en las condiciones experimentales empleadas puede concluirse que la fotopolimerización en menor tiempo e interposición de material restaurador afecta significativamente la calidad de polimerización evaluada mediante los valores de microdureza, pero la proporción bottom/ top no fue afectada en la variación en el tiempo de polimerización.

2.
Rev. estomatol. Hered ; 32(1): 30-35, ene.-mar 2022. tab
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1389059

ABSTRACT

RESUMEN Antecedentes: Las resinas compuestas tipo Bulk-Fill (BF) son usadas en piezas posteriores con preparaciones extensas y profundas. Uno de sus beneficios más resaltantes es que, puede ser utilizada en incrementos de 4 a 5 mm, disminuyendo el tiempo de trabajo clínico. Sin embargo, en dientes con tratamientos de conductos estas preparaciones podrían tener mayor profundidad. Objetivos: Determinar el tiempo de fotoactivación necesario para polimerizar una resina Bulk-Fill ubicada en zonas profundas. Material y Métodos: En el presente estudio experimental in vitro, se confeccionaron especímenes de resina compuesta Filtek One Bulk Fill (3M ESPE, St. Paul, EE.UU.) de 5x5x5 mm color A2 fotoactivado a una distancia/tiempo de 0 mm/10 s, 0 mm/20 s, 3 mm/10 s, 3 mm/20 s, 3 mm/30 s y 3 mm/40 s (n=5). La microdureza superficial se registró en la superficie y en la base de cada espécimen. Resultados: El mayor valor de microdureza se registró en el grupo BF 0 mm/20 s y BF 3 mm/40 s (p<0,05), seguido por los grupos BF 3 mm/20 s y BF 3 mm/30 s (p>0,05). Los menores valores de microdureza se encontraron en los grupos BF 0 mm/10 s y BF 3 mm/10 s. Conclusión : Se requiere de 40 s de fotoactivación para polimerizar una resina Bulk-Fill ubicada en zonas profundas, cuando la lámpara está a una distancia de 3 mm de la superficie de la resina.


ABSTRACT Background: Bulk-fill composite resins (BF) are used in posterior restorations with extensive and deep preparations. One of the most outstanding benefits is that it can be used in increments of 4 to 5 mm, reducing clinical working time. However, in teeth with root canal treatment, these preparations could be deeper. Objectives: To determine the photoactivation time necessary to polymerize a Bulk-Fill resin located in deep areas. Material and Methods: In the present experimental in vitro study, specimens of Filtek One Bulk Fill composite resin (3M ESPE, St. Paul, USA) of 5x5x5 mm color A2 photoactivated at a distance/time of 0 mm/10 s, 0 mm/20 s, 3 mm/10 s, 3 mm/20 s, 3 mm/30 s and 3 mm/40 s (n=5) were fabricated. Surface microhardness was recorded on the surface and at the base of each specimen. Results: The highest microhardness value was recorded in group BF 0 mm/20 s and BF 3 mm/40 s (p<0.05), followed by groups BF 3 mm/20 s and BF 3 mm/30 s (p>0.05). The lowest microhardness values were found in the BF 0 mm/10 s and BF 3 mm/10 s groups. Conclusion: It takes 40 s of photoactivation to polymerize a Bulk-Fill resin located in deep areas, when the lamp is 3 mm away from the resin surface.

3.
Rev. Ateneo Argent. Odontol ; 64(1): 77-82, 2021.
Article in Spanish | LILACS | ID: biblio-1252984

ABSTRACT

A pesar de los avances e innovaciones de los materiales dentales, la microfiltración marginal y la contracción durante la polimerización continúan siendo una de las causas principales del fracaso de los tratamientos en odontología restauradora. Un sellado marginal correcto será posible cuando las fuerzas de adhesión superen las fuerzas generadas por la contracción de polimerización y las fuerzas generadas por los cambios dimensionales térmicos posteriores a la polimerización, por lo que investigaciones previas demostraron que estas limitaciones pueden ser superadas con el uso de resinas Bulk Fill como material de relleno de cavidades extensas y profundas de dientes posteriores. Estas resinas. de relleno masivo, están recibiendo atención, principalmente porque se pueden colocar, a diferencia de las resinas convencionales, en incrementos de 4 mm sin afectar la contracción de la polimerización, la adaptación de la cavidad o el grado de conversión. El objetivo de la presente revisión bibliográfica es describir la contracción de polimerización y la consecuente filtración marginal que sufren las resinas compuestas para el sector posterior Bulk Fill con base de datos de la literatura (AU)


Despite advances and innovations in dental materials, marginal microfiltration and shrinkage during polymerization continue to be one of the main causes of treatment failure in Restorative Dentistry. A correct marginal seal will be possible when the adhesion forces exceed the forces generated by polymerization contraction and the forces generated by post-polymerization thermal dimensional changes, for which previous research has shown that these limitations can be overcome with the use of Bulk Fill resins as filling material for large and deep posterior tooth cavities, these massive filling resins are receiving attention mainly because they can be placed, unlike conventional resins, in 4 mm increments without affecting polymerization shrinkage. , cavity adaptation or degree of conversion. The objective of the present bibliographic review is to describe the polymerization contraction and consequent marginal filtration suffered by Composite Resins for the Bulk Fill posterior sector with a literature database (AU)


Subject(s)
Humans , Dental Marginal Adaptation , Composite Resins , Dental Leakage , Polymerization , Materials Testing , Dental Cavity Preparation , Dental Restoration, Permanent/instrumentation
4.
Odovtos (En línea) ; 22(3)dic. 2020.
Article in English | LILACS, SaludCR | ID: biblio-1386494

ABSTRACT

Abstract Avoiding biofilm formation on dentures is associated with maintaining the surface properties of acrylic-based dentures. The aim of the study is to investigate the effects of two different cleaning agents (Corega and Klorhex 0.2% chlorhexidine gluconate) on surface roughness of the denture regarding efficacy of curing procedures. A total of sixty disc-shaped specimens were prepared with two different methods as long and short curing processes. The specimens were divided into subgroups according to the immersion solutions (distilled water, Corega tablet group and Klorhex 0.2% chlorhexidine gluconate group) (n=10). The samples were kept in a solution for 8 hours per day during a month. The average Ra1 (before exposure to the cleanser agent) and Ra2 (after exposure to the cleanser agent) of each sample was measured. A two- way ANOVA and post hoc Tukey test was used for statistical analysis. The solutions significantly increased the Ra values in both acrylic groups (p0.05). The long-term curing time is highly effective in decreasing the surface roughness of the acrylic base material.


Resumen Evitar la formación de biopelículas en las prótesis dentales se asocia con el mantenimiento de las propiedades de la superficie de las prótesis de base acrílica. El objetivo del estudio es investigar los efectos de dos agentes de limpieza diferentes (Corega y Klorhex 0,2% gluconato de clorhexidina) en la rugosidad de la superficie de la dentadura postiza en cuanto a la eficacia de los procedimientos de curado. Se prepararon un total de sesenta muestras en forma de disco con dos métodos diferentes como procesos de curado largos y cortos. Las muestras se dividieron en subgrupos según las soluciones de inmersión (agua destilada, grupo de pastillas Corega y grupo de gluconato de clorhexidina al 0,2%) (n=10). Las muestras se mantuvieron en una solución durante 8 horas al día durante un mes. Se midió el promedio de Ra1 (antes de la exposición al agente de limpieza) y Ra2 (después de la exposición al agente de limpieza) de cada muestra. Para el análisis estadístico se utilizó un ANOVA de dos vías y una prueba post hoc de Tukey. Las soluciones aumentaron significativamente los valores de Ra en ambos grupos acrílicos (p 0,05). El tiempo de curado a largo plazo es muy eficaz para disminuir la rugosidad de la superficie del material de base acrílica.


Subject(s)
Dental Prosthesis , Dental Disinfectants , Oral Hygiene
5.
Odovtos (En línea) ; 22(2)ago. 2020.
Article in English | LILACS, SaludCR | ID: biblio-1386480

ABSTRACT

Abstract: Aim: Sufficient polymerization remains as crucial for composites to prevent discoloration. Both LEDs and halogen units are used for polymerization and different curing modes are improved to overcome inadequate polymerization. This in vitro study investigated staining susceptibility of a nano-hybrid resin composite light-cured in different modes and immersed in different staining media. Methods: Disc-shaped specimens were prepared from nano-hybrid resin composite (Filtek Z550) and light- cured according to following modes: Halojen (GI), LED standard (GII), LED pulse (GIII) or LED ramp (GIV). Half of the specimens of each group (n=7) were stored in one of the staining media (red wine or coffee) for 10 min/day during experimental period. Measurements were performed using spectrophotometer according to CIEL*a*b system at baseline and on 7, 28 and 56 days. Colour differences (∆E) between groups were submitted to statistical analysis. Results: Regarding 7-day evaluation, colour change values of specimens immersed in coffee revealed no remarkable difference among curing modes (p>0.05); whereas specimens in GIV were significantly less stained compared to specimens in GII and GIII when immersed in red wine. Regarding 56- days of evaluation, specimens of GIV showed statistically significant colour change in red wine compared to other groups. However specimens in GI revealed the least staining after 56-days of coffee immersion, and this result was statistically different from LED groups. Conclusion: This study suggest that light-curing mode influences the staining susceptibility of the tested composite. Composites polymerized with halogen unit showed lower staining than all LED modes. Despite novel light sources, halogen units may still used reliably at clinics.


Resumen: Objetivo: La polimerización suficiente sigue siendo crucial para que los compuestos eviten la decoloración. Tanto los LED como las unidades halógenas se utilizan para la polimerización y se mejoran los diferentes modos de curado para superar la polimerización inadecuada. Este estudio in vitro investigó la susceptibilidad a la tinción de un compuesto de resina nano-híbrida curado a la luz en diferentes modos y se sumergió en diferentes medios de tinción. Métodos: Las muestras en forma de disco se prepararon a partir de un compuesto de resina nano-híbrida (Filtek Z550) y se curaron con luz de acuerdo con los siguientes modos: Halojen (GI), estándar de LED (GII), pulso de LED (GIII) o rampa de LED (GIV). La mitad de las muestras de cada grupo (n = 7) se almacenaron en uno de los medios de tinción (vino tinto o café) durante 10 minutos / día durante el período experimental. Las mediciones se realizaron utilizando un espectrofotómetro de acuerdo con el sistema CIEL * a * b en la línea de base y en 7, 28 y 56 días. Las diferencias de color (∆E) entre los grupos se sometieron a análisis estadístico. Resultados: Con respecto a la evaluación de 7 días, los valores de cambio de color de las muestras sumergidas en café no revelaron diferencias notables entre los modos de curado (p> 0.05); mientras que las muestras en GIV se tiñeron significativamente menos en comparación con las muestras en GII y GIII cuando se sumergieron en vino tinto. Con respecto a los 56 días de evaluación, las muestras de GIV mostraron un cambio de color estadísticamente significativo en el vino tinto en comparación con otros grupos. Sin embargo, las muestras en GI revelaron la menor tinción después de 56 días de inmersión en el café, y este resultado fue estadísticamente diferente de los grupos LED. Conclusión: este estudio sugiere que el modo de fotopolimerización influye en la susceptibilidad de tinción del material compuesto probado. Los compuestos polimerizados con una unidad halógena mostraron una tinción más baja que todos los modos LED. A pesar de las nuevas fuentes de luz, las unidades halógenas todavía pueden usarse de manera confiable en las clínicas.


Subject(s)
Tooth Discoloration/diagnosis , Composite Resins , Light-Curing of Dental Adhesives/instrumentation
6.
Int. j. odontostomatol. (Print) ; 14(1): 60-66, mar. 2020. tab, graf
Article in English | LILACS | ID: biblio-1056502

ABSTRACT

ABSTRACT: The objective of the study was to evaluate marginal adaptation of Class II mesial-occlusal-distal (MOD) restorations before and after thermo-mechanical loading and volumetric shrinkage of the bulk-fill vs conventional composite resin. For marginal adaptation assessment, 24 Class II MOD cavities with cervical margins extending 1.0 mm below (distal) and 1.0 mm beyond (mesial) the cement-enamel junction were prepared in extracted human molars. The teeth were filled as follows: Group A - bulk-fill with SureFil SDR flow (first increment, 4 mm; second increment, 2 mm); Group B - bulk-fill with SureFil SDR flow as a base (first increment, 4 mm) and covered with the conventional nanohybrid composite Esthet-X HD (second increment, 2 mm); and Group C - incrementally filled with Esthet-X HD. Marginal adaptation was evaluated by scanning electron microscopy before and after thermomechanical loading (240,000 loading cycles and simultaneous 600 thermal cycles). To evaluate volumetric polymerization shrinkage, a semi-spherical mold was filled with the tested composites and placed in an AccuVol device after light curing. Both before and after loading, marginal adaptation in cervical dentin was superior (p < 0.05) for Groups A and B compared with Group C. In cervical enamel, Group B showed better marginal adaptation than Group C, and Group A presented intermediary results, between Groups B and C. Furthermore, bulk-fill flow resulted in greater shrinkage than Esthet-X HD. A significant improvement of marginal adaptation was observed when bulkfill flow was used instead of conventional composite resin both before and after thermomechanical loading. However, the bulk-fill flow presented higher volumetric polymerization shrinkage than the conventional composite.


RESUMEN: El objetivo de este trabajo consistió en evaluar la adaptación marginal de las restauraciones mesiales-oclusales-distales (MOD) de Clase II antes y después de la carga termo-mecánica y la contracción volumétrica de la carga compuesta de resina "bulk-fill" en comparación con resina convencional. Para la evaluación de adaptación, se prepararon 24 cavidades MOD de Clase II en molares humanos extraídos, los que se restauraron de la siguiente manera: Grupo A: restaurado con resina fluida Bulk-Fill SureFilSDR (primer incremento, 4 mm; segundo incremento, 2 mm); Grupo B: restaurado con resina fluida Bulk-Fill SureFil SDR (primer incremento, 4 mm) y cubierto con resina compuesta nanohíbrida Esthet-X HD (segundo incremento, 2 mm); y Grupo C - rellenado incrementalmente con Esthet-X HD. La adaptación marginal se evaluó mediante microscopía electrónica de barrido antes y después de la carga termomecánica (240.000 ciclos de carga y 600 ciclos térmicos simultáneos). Para evaluar la contracción volumétrica de la polimerización, se llenó un molde semiesférico con los compuestos probados y se colocó en un dispositivo AccuVol después del fotopolimerización. Tanto antes como después de la carga, la adaptación marginal en la dentina cervical fue superior (p <0,05) para los grupos A y B en comparación con el grupo C. En el esmalte cervical, el grupo B mostró una mejor adaptación marginal que el grupo C, y el grupo A presentó resultados intermedios, entre Grupos B y C. Se observó una mejora significativa de la adaptación marginal al utilizar la resina fluida Bulk-Fill en lugar de resina compuesta convencional tanto antes como después de la carga termomecánica. Sin embargo, la resina fluida 'Bulk-Fill' presentó una mayor contracción volumétrica de polimerización que el compuesto convencional.


Subject(s)
Humans , Dental Marginal Adaptation , Composite Resins , Dental Cavity Preparation/instrumentation , Dental Restoration, Permanent/methods , Malocclusion, Angle Class II , Stress, Mechanical , Ethics Committees , Dental Restoration Wear , Dental Cavity Preparation/standards , Polymerization
7.
Int. j. odontostomatol. (Print) ; 13(3): 279-286, set. 2019. tab, graf
Article in English | LILACS | ID: biblio-1012423

ABSTRACT

ABSTRACT: The objective of this study was to compare the polymerization shrinkage of Eclipse photopolymerization resin for prosthesis based on urethane dimethacrylate (UDMA) with that of three heat-cured acrylic resins based on polymethyl methacrylate (PMMA) after the polymerization process and immersion in water. A total of 40 prostheses were fabricated on a standard metallic upper edentulous model: group 1, Eclipse; group 2, Triplex hot; group 3, Veracril; and group 4, Lucitone 199. Subsequently, the polymerization contraction was tested using a microscope in which measurements were made in micrometres at 3 points located in the middle parts of the right and left sides and the middle part of the palate at three time points once the prosthesis was completed, after 30 days of immersion in water for 8 hours a day at a temperature of 37 °C, and after cutting the prosthesis at the level of the second premolar. ANOVA revealed that the contraction of the polymerization no statistically significant differences between the groups, (P> 0.05). The type of resin and its interaction with the processing method behaves similarly for all test resins. The Veracril heat-cured resin obtained the lowest contraction value in the three measurements (mm) and the highest value was obtained with the Eclipse photopolymerization resin. The Eclipse resin exhibited no lower polymerization shrinkage compared to conventional acrylic resins based on polymethyl methacrylate (PMMA), however it was not significantly affected by immersion in water.


RESUMEN: El objetivo de este estudio fue comparar la contracción de polimerización de la resina de fotopolimerización Eclipse para prótesis basadas en dimetacrilato de uretano (UDMA) con la de tres resinas acrílicas curadas con calor a base de polimetacrilato de metilo (PMMA) después del proceso de polimerización e inmersión en agua. Se fabricaron un total de 40 prótesis en un modelo edéntulo superior metálico estándar: grupo 1, Eclipse; grupo 2, triplex caliente; grupo 3, veracril; y grupo 4, Lucitone 199. Posteriormente, la contracción de la polimerización se probó utilizando un microscopio en el que se realizaron mediciones en micrometros en 3 puntos ubicados en las partes medias de los lados derecho e izquierdo y la parte media del paladar en tres puntos de tiempo una vez la prótesis se completó, después de 30 días de inmersión en agua durante 8 horas al día a una temperatura de 37 °C, y después de cortar la prótesis a nivel del segundo premolar. ANOVA reveló que la contracción de la polimerización no presenta diferencias estadísticamente significativas entre los grupos, (P> 0,05). El tipo de resina y su interacción con el método de procesamiento se comportan de manera similar para todas las resinas de prueba. La resina curada con calor Veracril obtuvo el valor de contracción más bajo en las tres mediciones (mm) y el valor más alto se obtuvo con la resina de fotopolimerización Eclipse. La resina Eclipse no mostró una contracción de polimerización menor en comparación con las resinas acrílicas convencionales basadas en polimetilmetacrilato (PMMA), sin embargo, no se vio afectada significativamente por la inmersión en agua.


Subject(s)
Composite Resins/chemistry , Resin Cements/chemistry , Dental Stress Analysis/methods , Denture Bases , Polymerization , Acrylic Resins , In Vitro Techniques , Hydrogel, Polyethylene Glycol Dimethacrylate , Dental Stress Analysis/instrumentation
8.
Odontol. vital ; (30): 65-72, ene.-jun. 2019. tab, graf
Article in Spanish | LILACS, SaludCR | ID: biblio-1091415

ABSTRACT

Resumen Objetivo: Comparar el grosor y homogeneidad de la capa de cementación entre un cemento de resina fotodependiente y una resina fluida. Materiales y métodos: Para la obtención de la muestra se talló la preparación en un diente de marfilina, el cual fue escaneado y luego replicado 92 veces en un polímero ABS. La muestra se dividió en 2 grupos con 46 muestras cada uno. Se realizó la cementación de las carillas con resina fluida Tetric N-Flow en el grupo G1, y con cemento de resina fotodependiente VariolinkEsthetic en el grupo G2. Cada muestra fue previamente lavada con alcohol de 70°, luego secada y se aplicó una capa de adhesivo TetricN-Bond. Se utilizó presión digital para lograr el asentamiento final de las carillas. Finalmente se realizó un corte medial y uno paramedial para obtener muestras de 2 mm aproximadamente, las cuales se observaron y midieron en un microscopio óptico. Resultados: El promedio de grosor para Tetric N-Flow fue de 119μm en incisal, 113μm en medio y 107μm en cervical. Para VariolinkEsthetic el promedio fue de 117μm, 112μm y 110μm en incisal, medio y cervical respectivamente. La homogeneidad fue de un 93,3% para G1 y 91,3% para G2. Conclusión: No existe diferencia significativa en el grosor y homogeneidad de la capa de cementación realizado con resina fluida y con cemento de resina fotodependiente.


Abstract Objective: Compare the thickness and homogeneity of the cementing layer between a light-cure resin cementand a flowable resin. Materials and methods: To obtain the sample, the preparation was carved in a replica of tooth 1.1 (EWL modelteeth, Kavo), which was scanned and then replicated 92 times in an ABS polymerby 3D printing. The simple was divided into 2 groupswith 46 sample seach. The cementation of the veneres was performed with Tetric N-Flow flowable resin in the G1 group, and with Variolink Esthetic light-cure resin cement in the G2 group. Each simple was previously washed with 70° alcohol, then dried and a layer of Tetric N-Bond was applied. Digital pressure was used to achieve the final settlement of the veneers. Finally, a medial and a paramedial section were made to obtain approximately 2 mm thick samples. The cementation layer was observed with an optical microscope. Results: The average thickness for Tetric N-Flowwas 119μm in incisal, 113μm in medium and 107μm in cervical. For Variolink Esthetic the average was 117μm, 112μm and 110μm in incisal, middle and cervical respectively. The homogeneity was 93.3% for G1 and 91.3% for G2. Conclusion: There is no significant difference in the thickness and homogeneity of the cementing layer made with flowable resin and with light-cure resincement.


Subject(s)
Resin Cements/therapeutic use , Dental Cements/therapeutic use , Dental Veneers , Polymerization , Fluorocarbon Polymers/analysis , Cementation
9.
Rev. mex. ing. bioméd ; 40(1): e201838, Jan.-Apr. 2019. tab, graf
Article in Spanish | LILACS | ID: biblio-1043132

ABSTRACT

Resumen Se describe el proceso para obtener un adhesivo sensible a la presión (PSA). Este PSA está formado por un copolímero de acrilato de 2-etilhexil (2-EHA) / metacrilato de metilo (MMA) en una relación 80:20 que se polimerizó mediante una técnica de polimerización en emulsión. Se añadieron nanopartículas de óxido de zinc (NPZnO) a este copolímero, que se sintetizaron previamente y se modificaron superficialmente con 3-aminopropil-3-toxisilano (APTES) y dimetilsulfóxido (DMSO) para mejorar su dispersión en la matriz de copolímero. Los nanocompuestos obtenidos se caracterizaron por espectroscopía infrarroja (FTIR), calorimetría diferencial de barrido (DSC) y pruebas de adhesión al delaminado. Además, se determinó la actividad antimicrobiana contra S. aureus y S. pyogenes, así como la citotoxicidad en células humanas (HeLa). Los resultados demostraron que la adición de las nanopartículas de NPZnO al copolímero incrementa la temperatura de transición vítrea (Tg) así como las propiedades antimicrobianas del adhesivo mejorando a su vez su adhesión superficial. Con respecto al comportamiento adhesivo, el PSA con NPZnO sin modificar mostró una mayor resistencia al delaminado, esto quiere decir que las nanopartículas incrementan la fuerza cohesiva y proporcionan resistencia a temperaturas elevadas, lo cual sería beneficioso a su aplicación final. Finalmente, los resultados de citotoxicidad mostraron que la incorporación de NPZnO al PSA disminuye la viabilidad celular, sin embargo no se considera tóxico acorde a la norma ISO 10993 test for in vitro cytotoxicity.


Abstract The process for obtaining a pressure sensitive adhesive (PSA) is described. This PSA is formed by an acrylate copolymer of 2-ethylhexyl (2-EHA) / methyl methacrylate (MMA) in an 80:20 ratio which was polymerized by emulsion polymerization technique. Zinc oxide nanoparticles (NPZnO) were added to this copolymer, which were previously synthesized, and surface modified with 3-aminopropyltretoxysilane (APTES) and dimethyl sulfoxide (DMSO) to improve its dispersion in the copolymer matrix. The obtained nanocomposites were characterized by infrared spectroscopy (FTIR), differential scanning calorimetry (DSC) and T-peel adhesion tests. In addition, the antimicrobial activity against S. aureus and S. pyogenes as well as the cytotoxicity in human cells (HeLa) were determined. The results demonstrated that the ZnO nanoparticles incorporation enhanced the glass transition temperature (Tg) and the antimicrobial activity of PSA copolymer as well as its surface adhesion. It was confirmed that NPZnO modification with APTES increased its antimicrobial activity. Regarding adhesive behavior, PSA with unmodified NPZnO showed a greater peel resistance. This indicates that these nanoparticles enhances the cohesive force and induces a better high temperature performance, which is beneficial for the final application. Finally, cytotoxicity results showed that the incorporation of NPZnO to PSA decreases the cell viability, however this PSA is not toxic according to the standard ISO 10993 test for in vitro cytotoxicity.

10.
J. oral res. (Impresa) ; 8(1): 37-41, feb. 28, 2019. tab, ilus
Article in English | LILACS | ID: biblio-1145265

ABSTRACT

Background: Auto-polymerized acrylic resins are commonly used in many applications in dentistry including in maxillofacial rehabilitation such as interim prostheses, denture repair, reline, orthodontic appliances, record base, among others. These substances, however, have some negative aspects such as poor mechanical properties. Aim: The objective of the current study was to evaluate the effect of incorporating zinc oxide nanoparticles to auto-polymerized acrylic resins on their flexural strength. Materials and methods: Thirty specimens were made from auto-polymerized acrylic resins, divided into three main groups (1 control and 2 experimental). Each group had ten specimens. The two experimental groups comprised the zinc oxide powder at 1% and 2% concentrations, respectively. Acrylic specimens were fabricated with the dimension of 65mm length, 10mm width and 2.5mm thickness according to ISO 1567 specification 1999. Each specimen was subjected to the flexural strength test by a universal testing machine. The crosshead speed for the flexural strength test was 5mm/min until fracture occurred. The SPSS version 16 was utilized for the statistical analysis. The ANOVA and Tukey were used for the comparison among all groups. Results: there was a significant increase (p<0.001) in the flexural strength of the acrylic resins following the addition of zinc oxide particles (control group: 133.27 SD 1.73, ZnO 1%: 154.28 SD 2.90, ZnO 2%: 176.45 SD 0.94). Conclusions: The incorporation of zinc oxide nanoparticles has a significant effect on the flexural strength of auto-polymerized acrylic resins.


Antecedentes: Las resinas acrílicas autopolimerizadas se usan comúnmente en muchas aplicaciones en odontología, incluyendo la rehabilitación maxilofacial, en prótesis provisionales, reparación de prótesis, revestimientos, en aparatos de ortodoncia, bases de registro, entre otros. Estas sustancias, sin embargo, tienen algunos aspectos negativos tales como propiedades mecánicas deficientes. Objetivo: el objetivo del presente estudio fue evaluar el efecto de la incorporación de nanopartículas de óxido de zinc en la resistencia a la flexión de resinas acrílicas autopolimerizadas. Materiales y métodos: Treinta muestras de resinas acrílicas autopolimerizadas fueron hechas, divididas en tres grupos principales (un grupo control y dos experimentales), cada grupo con diez especímenes. Se incorporó polvo de óxido de zinc en los dos grupos experimentales, en concentraciones de 1% y 2%, respectivamente. Las muestras de acrílico se fabricaron con una dimensión de 65mm de longitud, 10mm de ancho y 2,5mm de espesor según la especificación ISO 1567 1999. Cada muestra se sometió a la prueba de resistencia a la flexión mediante una máquina de prueba universal. La velocidad de la cruceta para la prueba de resistencia a la flexión fue de 5mm/min hasta que se produjo la fractura. Se utilizó la versión SPSS 16 para el análisis estadístico. El ANOVA y Tukey se utilizaron para la comparación entre todos los grupos. Resultados: Se observó un aumento significativo (p<0.0 01) en la resistencia a la flexión de las resinas acrílicas luego de la adición de partículas de óxido de zinc (grupo de control: 133,27 SD 1,73 MPa, ZnO 1%: 154,28 SD 2,90 MPa, ZnO 2%: 176,45 SD 0,94 MPa). Conclusiones: La incorporación de nanopartículas de óxido de zinc tiene un efecto significativo en la resistencia a la flexión de las resinas acrílicas autopolimerizadas.


Subject(s)
Humans , Zinc Oxide , Acrylic Resins/chemistry , Dental Materials/chemistry , Nanoparticles/chemistry , Outcome Assessment, Health Care , Flexural Strength
11.
Rev. Fac. Odontol. (B.Aires) ; 34(78): 49-55, 2019. tab, graf
Article in Spanish | LILACS | ID: biblio-1116910

ABSTRACT

El objetivo de este estudio fue analizar el comportamiento, contracción volumétrica, de diferentes resinas compuestas de fotopolimerización, expuestas a variadas condiciones de incidencia lumínica. Se tomaron volúmenes estandarizados de 7 resinas compuestas (microhíbridas y nanohíbridas y nanoparticulados) que se colocaron sobre una línea de referencia en portaobjetos, cubriéndose luego con otro y aplicando una fuerza previamente establecida. Se midió luego con un calibre electrónico la variaciones en el diámetro de la muestra bajo tres situaciones diferentes: luz ambiente (natural), luz foco (halógena), luz artificial (tubos fluorescentes) y sus combinaciones. Resultados: Se observó la mayor variación porcentual al exponer a las muestras simultáneamente a la luz ambiente, artificial y operatoria, siendo los valores más altos de reducción para las resinas compuestas Brilliant NG Coltene (Dentina) y Miris 2 Coltene (Dentina) con -2.52% y -2.7% respectivamente. Conclusión: existieron modificaciones en el volumen de todos los materiales expuestos a las diferentes condiciones de luz y tiempo de exposición. Comparando los resultados con el estudio previo (2007) se pude inferir que los materiales usados en el presente estudio resultaron más fotosensibles, dado que a similar exposición, aumentaron y/redujeron su tamaño en mayor medida (AU)


Subject(s)
Composite Resins/chemistry , Curing Lights, Dental , Polymerization , Time Factors , Materials Testing , Analysis of Variance , Dentin , Light
12.
Rev. biol. trop ; 66(4): 1412-1420, oct.-dic. 2018. tab, graf
Article in Spanish | LILACS | ID: biblio-1003334

ABSTRACT

Resumen Nuevos agentes antimaláricos a partir de plantas son estudiados como alternativas en el tratamiento de la malaria. Los principales antimaláricos como la cloroquina tienen varios mecanismos de acción contra parásitos, uno de ellos es la inhibición de polimerización del grupo hemo, modelo que ha permitido el diseño de nuevos candidatos antimaláricos. En este sentido, el objetivo de este trabajo fue evaluar extractos de plantas de género Piper y Calophyllum sobre la capacidad de inhibición de la β-hematina. Se informa las concentraciones inhibitorias de la formación de β-hematina por parte de 40 extractos de diferente polaridad obtenidos a partir de las especies P. piedecuestanum, C. brasiliense, C. longinforium, y Calophyllum. sp. 19 extractos mostraron un mayor potencial para inhibir la formación de β−hematina con CI50 < 3mg / ml. Estas actividades respaldan principalmente, futuros estudios con el género Calophyllum, en el desarrollo y descubrimiento de nuevas sustancias antiplasmodiales con modos de acción conocido.(AU)


Abstract New antimalarial agents from plants are studied as alternatives in the treatment of malaria. The main antimalarials such as chloroquine have several mechanisms of action against parasites, one of which is the inhibition of polymerization of the heme group, a model that has allowed the design of new antimalarial candidates. In this sense the objective of this work was to evaluate extracts of genus Piper and Calophyllum plants on the inhibition capacity of β-hematin. Inhibitory concentrations of β-hematin are reported from 40 extracts of different polarity obtained from the species P. piedecuestanum, C. brasiliense, C. longinforium, and Calophyllum. sp. 19 extracts showed a greater potential to inhibit β-hematin with IC50 < 3 mg/ml. These activities mainly support future studies with the genus Calophyllum in the development and discovery of new antiplasmodial substances with known modes of action.(AU)


Subject(s)
Chloroquine/pharmacology , Polymerization/drug effects , Heme-Binding Proteins , Malaria/drug therapy
13.
Rev. ADM ; 75(4): 228-236, jul.-ago. 2018. ilus
Article in Spanish | LILACS | ID: biblio-916343

ABSTRACT

Los trastornos temporomandibulares (TTM) constituyen un problema en la población en general cuyos signos y síntomas tienen un carácter multifactorial que debe ser abordado de manera interdisciplinaria para poder brindar una mejor oportunidad de éxito y estética en los tratamientos. Las guardas oclusales forman parte del tratamiento en los TTM, se deben conocer sus indicaciones, contraindicaciones, ventajas y desventajas, debido a que las guardas oclusales cumplen ciertas funciones y objetivos. La guarda oclusal elaborada por la técnica de polimerización en microondas (GOTMI) reduce signifi cativamente el tiempo de elaboración en el laboratorio, proporciona un aparato de alta calidad y baja porosidad. La GOTMI es un aparato que proporciona un método indirecto y no invasivo modifi cando la oclusión, recuperando el tejido u órganos dentales perdidos, reorganiza la actividad refl eja neuromuscular, relaja la musculatura, promueve el reposicionamiento del disco articular, protege los dientes, oclusión y estructuras de sostén periodontal, además de mejorar la estética y la autoestima del paciente. La GOTMI disminuye el dolor en la ATM y la neuromusculatura, proporciona alivio a las cefaleas tensionales, elimina las interferencias oclusales, es un distribuidor de fuerzas oclusales, además de provocar un mayor número de contactos de igual intensidad de fuerza contra la superfi cie oclusal en todos los dientes. Existen varios métodos para la confección de las guardas oclusales, en el presente trabajo se describe la elaboración de una guarda oclusal programada con los principios de oclusión orgánica. La técnica de polimerización por microondas es innovadora debido a que este proceso consiste en la generación de calor dentro de la resina mediante ondas electromagnéticas producidas por un generador llamado magnetrón. Las moléculas de metilmetacrilato son capaces de orientarse por el campo electromagnético a una frecuencia de 2,450 MHz, y cambian su dirección cinco billones de veces por segundo aproximadamente, lo que implica numerosas colisiones intermoleculares y causa una rápida polimerización (AU)


Temporomandibular disorders (TMD) are a problem in the general population whose signs and symptoms have a multifactorial character that must be addressed by an interdisciplinary team to provide a better chance of success and aesthetic treatments. Occlusal guards are part of TMD treatment, you should know the indications, contraindications, advantages, and disadvantages, because the occlusal guards perform certain functions and objectives. The occlusal guard by Iztacala modifi cation provides an indirect and noninvasive method modifying occlusion, recovering the lost dental tissue or organs, reorganizes the neuromuscular refl ex activity, relaxes the muscles, promotes articular disc repositioning, protecting the teeth and supporting occlusion structures, it also improves aesthetics and self-esteem. The occlusal guard Iztacala modifi cation has the advantage of decreasing TMJ pain, provides relief to tension headaches, elimination of occlusal interferences, is a distributor of occlusal forces as well as causing a greater number of contacts equal intensity of force against the occlusal surface of all teeth. There are several methods for the fabrication of occlusal guards, in this paper the development of an occlusal guard programmed with the principles of organic occlusion is described, using as a basis a rigid acetate and acrylic for programming, in addition to providing your cosmetic use and function. The acquisition or denial of treatment with an occlusal splint depends on the choice, preparation, occlusal guard adjustment and patient cooperation (AU)


Subject(s)
Humans , Dental Occlusion , Microwaves , Occlusal Splints , Polymerization , Temporomandibular Joint Disorders , Acetates , Dental Articulators , Models, Dental , Polymers
14.
Rev. cient. odontol ; 6(1): 29-38, ene.-jun. 2018. ilus, tab
Article in Spanish | LILACS | ID: biblio-998742

ABSTRACT

Objetivo: Comparar, a las 48 horas, la microdureza superficial de las resinas para reconstrucción de muñones Luxa- core DMG America, Absolute Dentin Parkell y Z350 XT 3M. Materiales y métodos: El grupo de estudio estuvo conformado por 33 discos de resina, distribuidos en tres subgrupos: dos experimentales cada uno conformado por (n = 11), y uno control (n = 11). Los dos primeros grupos son resinas de foto activación y el tercero, una resina de activación dual. Estos fueron sometidos al instrumento microdurómetro Vickers, marca LG, en el laboratorio de ensayos mecánicos. Se aplicó una carga de 200 gramos fuerza por 10 segundos para cada indentación. El análisis estadístico se realizó con ayuda del programa SPSS versión 24 y se realizó la prueba de Anova y la prueba de comparación múltiple de Tukey. Resultados: Luego del ensayo de microdureza Vickers (VHN), los resul- tados fueron: para G1, el valor promedio para la variable microdureza fue 55,24 ± 1,7 VHN; el G2 arrojó un valor promedio de 54,34 ± 3,82 VHN, y para G3 fue de 75.66 ± 4.4 VHN. Conclusión: Las resinas compuestas foto activadas, como material de reconstrucción de muñones sometidos a la prueba de microdureza superficial, mostraron propiedades mecánicas mejoradas en comparación con las resinas duales evaluadas. (AU)


Objective: Compare the superficial microhardness at 48 hours of the core build-up resins Luxacore DMG America, Absolute Dentin PARKELL and Z350 XT 3M. Materials and methods: The study group consisted of 33 resin discs, distrib-uted in three sub-groups: two experi-mental groups (n = 11) and one control group (n = 11). The first two groups were photo activation resins and the third group was a dual activation resin, subjected to the Micro-Vickers Hardness Tester - LG Brand in the mechanical testing labo-ratory. A test force of 200 grams was applied for 10 seconds for each indenta-tion. Statistical analysis was conducted with the help of the SPSS version 24 program and the Anova test and Tukey multiple comparison test were performed. Results: Following the Vickers micro-hardness test (vhn), the mean results for the indentations are shown in Table 1 in vhn values. f or g1 the average microhardness variable was 55.24 ± 1.7 vhn. g2 exhibited an average value of 54.34 ± 3.82 vhn. the average micro-hardness value for G3 was 75.66 ± 4.4 vhn.Conclusions: Composite photo activated resins as a core build-up mate-rial subjected to surface microhardness testing displayed improved mechanical properties compared to the dual resins evaluated. (AU)


Subject(s)
Dental Cements , Polymerization , Hardness
15.
Rev. mex. ing. bioméd ; 37(3): 165-179, Sep.-Dec. 2016. graf
Article in English | LILACS | ID: biblio-961322

ABSTRACT

Abstract An artificial liver support system is based on the functional hepatocytes being cultured inside a bioreactor; this technique has being used as an effective therapy for treating chronic liver diseases in recent times. This work evaluates different parameters such as cell viability and metabolic function of the hepatocytes when cultured on a hybrid scaffold. The scaffold was built using a polypyrrole plasma coated polymer layer seeded with endothelial matrix for efficient three-dimensional hepatocyte growth within a radial flow bioreactor. The flow rate inside the bioreactor was 7 ml / min. The parts for the bioreactor where either built using food-grade steel and/or glass or the scaffolds comprise a Poly (L-lactic acid)-coated polypyrrole iodine layer or not for HepG2 culture. The results show that the Poly (L-lactic acid)-coated scaffolds increased cell proliferation by 30%, protein production by 16% and albumin secretion by 40% compared with the non-coated scaffold. All experiments were performed thrice and data was analysed by ANOVA and Tukey statistic models with a p<0.05. The obtained results demonstrated that radial flow bioreactors in conjunction with hybrid scaffolds improve hepatocytes' physiological and functional properties and could be used as an alternative therapy for patients with liver diseases.


Resumen Un sistema de soporte hepático artificial se basa en utilizar hepatocitos funcionales cultivados en un biorreactor; esta técnica ha demostrado que se puede utilizar como una terapia eficaz para el tratamiento de enfermedades crónicas del hígado en los últimos tiempos. Este trabajo evalúa diferentes parámetros tales como la viabilidad celular y la función metabólica de los hepatocitos cuando se cultivan en un andamio híbrido. El andamio fue construido usando una capa de polímero recubierto de polipirrol plasma, se sembró con un cultivo tridimensional de células endoteliales y de hepatocitos dentro de un biorreactor de flujo radial. La velocidad de flujo en el interior del biorreactor fue de 7 ml / min. Las piezas para el biorreactor fueron construidas con acero de calidad alimentaria y / o vidrio. Los andamios control fueron de ácido L-poliláctico y a estos se les agrego un revestimiento de polipirrol-yodo para el cultivo de HepG2. Los resultados muestran que el ácido L-poliláctico recubierto, aumento la proliferación celular en un 30%, la producción de proteínas en un 16% y la secreción de albúmina por 40% en comparación con el andamio no recubierto. Todos los experimentos se llevaron a cabo tres veces y los datos se analizaron mediante modelos estadísticos ANOVA y Tukey con una p <0.05. Los resultados obtenidos demostraron que los biorreactores de flujo radial conjuntamente con andamios híbridos mejoran las propiedades fisiológicas y funcionales hepatocitos y podrían utilizarse como una terapia alternativa para los pacientes con enfermedades hepáticas crónicas.

16.
Rev. cient. odontol ; 4(2): 538-546, jul.-dic. 2016. ilus, tab, graf
Article in Spanish | LILACS, LIPECS | ID: biblio-999681

ABSTRACT

OBJETIVO: El objetivo de este estudio fue comparar el grado de conversión (GC) de cuatro cementos resinosos fotoactivados a través de un disco de disilicato de litio medido en dos tiempos: inicial y a las 24 horas. MATERIALES Y MÉTODOS: Se confeccionaron cinco especímenes para cada cemento evaluado : RelyXTM Veneer (RX), ChoiceTM2 (CH), NX3 NexusTM Light cure (NX) y Allcem Veneer (AC), los que fueron analizados con el Espectroscopio infrarrojo FTIR (Fourier Transmission Infrared Spectroscopy) para evaluar el GC inicial y luego almacenados durante 24 horas a 37º C realizándose una segunda medida. Todos los cementos evaluados fueron fotoactivados a través del test de ANOVA de un factor y el de comparaciones múltiples de Tukey. RESULTADOS: Se obtuvieron los siguientes resultados tanto para el GC inicial y a las 24 horas: RX (grupo control) 67.05 ± 0.22% y 76.87 ± 2.57%; CH 70.06 ± 1.52% y 84.80 ± 0.40%; NX 69.01 ± 0.52% y 81.62 ± 0.23%; AC 73,31 ± 0.40% y 85,22 ± 0.07%. Se encontraron diferencias estadísticamente significativas entre los grupos independientes y relacionados. CONCLUSIÓN: El cemento resinoso Allcem Veneer presenta un mejor GC comparado con las otras marcas. Todos los cementos aumentaron su GC significativamente a las 24 horas. (AU)


OBJECTIVE: The aim of this study was to compare the degree of conversion (DC) of four dental resin cements photoactivated through a lithium disilicate disk measured in two stages: initial and 24 hours. MATERIALS AND METHODS: Five especimens for each resin cement (RelyXTM Venner (RX), ChoiceTM 2 (CH), NX3 Nexus TM Light cure (NX) and Allcem Veneer (AC) were fabricated, which were analyzed by infrared spectroscopy FTIR (Fourier Transmission Infrared spectroscopy) to assess the initial DC and then stored for 24 hours at 37ºC performing a second measurement. All cements were photoactivated through a 1.5 mm thick lithium disilicate disk. ANOVA and Tukeys multiple comparison statistical test was performed. RESULTS: The following results were obtained for both the initial DC and 24 hours: RelyX Veneer (control group) 67.05 ± 0.22% y 76.87 ± 2.57%; Choice 2 70.06 ± 1.52% y 84.80 ± 0.40%; NX 3 96.01 ± 0.52% y 81.62 ± 0.23; Allcem Veneer 73,31 ± 0.40% y 85,22 ± 0.07%. Statistically significant differences were found between groups independent and connected. CONCLUSION: The resin cement Allcem Veneer has a better DC compared to other brands. All cements increased their DC significantly at 24 hours. (AU)


Subject(s)
Humans , Biocompatible Materials , Cementation , Resin Cements , Polymerization
17.
Rev. odontol. mex ; 19(4): 222-227, oct.-dic. 2015. tab, graf
Article in Spanish | LILACS | ID: biblio-961534

ABSTRACT

Objetivos: Determinar el espesor de tejido dental a través del cual se presente la fotopolimerización de la resina Prime Dent® con mínimo encogimiento y profundidad de curado adecuada. Método: Se obtuvieron 80 láminas de molares de 1, 2, 3 y 4 mm de espesor (20 por grupo). Se midió la contracción y se calculó el encogimiento de la resina polimerizando (Visilux 2, 3 M) a través de cada lámina (60 s, 400 mW/cm2). Se utilizó la técnica de bonded-disc. Se realizaron pruebas de profundidad de curado, midiendo el espesor de resina polimerizada de acuerdo con la especificación No. 27 ADA. Un grupo control sin tejido dental fue preparado para ambas propiedades. Los datos fueron analizados usando ANOVA con prueba de Tukey (p < 0.001). Resultados: Profundidad de curado: a medida que aumentó el espesor, ésta disminuyó, existiendo diferencia estadísticamente significativa en todos los grupos. El espesor que mostró menor encogimiento, cumpliendo con una profundidad de curado adecuada (ADA marca como valor mínimo, 1 mm) fue de 3 mm. Encogimiento: a medida que aumentó el espesor, éste disminuyó, no existiendo diferencia estadísticamente significativa entre los grupos de 2 y 3 mm. Conclusiones: De acuerdo con los resultados, es posible polimerizar a través de un espesor de 3 mm, por lo que no se recomienda polimerizar a través de un espesor de 4 mm. Es necesario obtener más propiedades mecánicas utilizando diferentes espesores de tejido dental.


Objectives: To determine the thickness of dental tissue through which Prime Dent Resin® might exhibit light-polymerization with minimum shrinkage and suitable curing depth. Method: 80 laminae measuring 1, 2, 3 and 4 mm thickness were obtained from molars (20 laminae per group). Contraction was measured and resin shrinkage was calculated by polymerization (Visilux 2, 3 M) though each lamina (60 s, 400 mW/cm2). Bonded-disk technique was used. Depth of curing tests were undertaken by measuring the thickness of polymerized resin according to ADA's specification number 27. A control group without dental tissue was prepared for both properties. Data were analyzed using ANOVA with Tukey test (p < 0.001). Results: Curing depth: curing depth decreased as thickness increased. All groups revealed statistically significant differences. The thickness that exhibited lesser shrinkage nonetheless meeting with suitable curing depth (ADA establishes minimum value of 1 mm) was the 3 mm group. Shrinkage: as thickness increased, shrinkage decreased; no statistically significant difference was reported for groups 2 and 3 mm. Conclusions: According to obtained results, it is possible to polymerize through a 3 mm thickness, therefore polymerization is not recommended through a 4 mm depth. It will be necessary to obtain further mechanical properties using different thicknesses of dental tissue.

18.
J. oral res. (Impresa) ; 4(6): 387-392, 2015. ilus, tab
Article in English | LILACS | ID: biblio-869003

ABSTRACT

Abstract: aim: to determine differences in marginal adaptation between a conventional composite resin and a monoincremental resin with sonic activation. Materials and methods: 32 composite resin discs of 2.5mm in diameter and 2mm thick were fabricated in a propylene matrix and distributed in 2 groups of 16 samples each. Groups 1 FiltekTMZ350XT resin; Group 2 SonicFillTM resin with sonic activation. The gap generated between the resin and the matrix as a result of the polymerization shrinkage was analyzed in microns using a microscope at a magnification of 40X. The percentage of the lineal polymerization shrinkage was also calculated. To calculate differences in marginal adaptation between the two resins statistical analysis was performed using the unpaired t-test. Results: The extent of the gaps measured in microns and their respective standard deviations were SonicFillTM 9.95 more less 3.05 and FiltekTMZ350XT 10.21 more less5.14 (p=.86). Conclusion: The use of the monoincremental resin system with sonic activation shows a marginal adaptation similar to that of conventional resin composites, with no statistically significant differences between the studied resins.


Resumen: determinar diferencias de adaptación marginal entre una resina compuesta convencional y una resina monoincremental activada sónicamente. Material y métodos: 32 discos fabricados de resina compuesta de 2.5 mm de diámetro y 2 mm de grosor en una matriz de propileno se distribuyeron en 2 grupos de 16 muestras cada uno: grupo 1 resina FiltekTM Z350X; grupo 2 resina SonicFillTM activada sónicamente. La brecha generada entre la resina y la matriz producto de la contracción de polimerización se midió en micrones en un microscopio con magnificación 40x. Para evaluar las diferencias de adaptación marginal entre las dos resinas se realizó análisis estadístico con un t-test de muestras no pareadas. Resultados: La amplitud de las brechas medidas en micrones y sus respectivas desviaciones estándar fueron: SonicFillTM 9.95 más menos 3.05 y FiltekTM Z350X 10.21 más menos 5.14 (p=.86). Conclusión: El uso del sistema de resina monoincremental activado sónicamente presenta similar adaptación marginal que la resina convencional, no existiendo diferencias estadísticamente significativas entre las resinas estudiadas.


Subject(s)
Humans , Dental Materials , Polymerization , Composite Resins/chemistry , Ultrasonics
19.
Acta odontol. latinoam ; 27(2): 72-76, Sept.2014. tab, graf
Article in English | LILACS | ID: lil-761852

ABSTRACT

El objetivo de este trabajo fue evaluar el efecto del curado adicional sobre la resistencia flexural y el módulo elástico de composites directos e indirectos. Se obtuvieron veinticuatro probetasprismáticas rectangulares de 2mm de lado y 25mm de largo, con los composites Belleglass, Premisa (Kerr), Adoro y Heliomolar (Ivoclar Vivadent). Cada uno de los materiales fue insertadocon un instrumento de Teflón® en un dispositivo ad-hoc de acero inoxidable, sobre el material se colocó una cinta de acetato y una placa de vidrio, y luego se ejerció presión uniforme sobre el conjunto con el fin de obtener una superficie lisa y plana. En todos los casos, la superficie de las probetas fue dividida en cuatro secciones de igual largo al diámetro de salida de la fibraóptica para asegurar la llegada de energía de activación a toda la masa de material; en cada una de ellas se activó la polimerización durante 20 segundos, con una lámpara halógena (Astralis 10, Ivoclar - Vivadent). Las muestras obtenidas fueron asignadas al azara dos grupos: con y sin curado adicional. En el grupo con curado adicional, los especímenes de Adoro recibieron un curado adicional de 25 minutos en el dispositivo Lumamat 100 (IvoclarVivadent), mientras que el resto de los materiales fueron sometidos a 20 minutos en BelleGlass HP (Kerr). Luego de dichos procedimientos, se eliminaron los excesos con papel abrasivo de granulometría creciente bajo flujo de agua y se almacenaron en agua destilada a 37º C durante 24 horas. La resistencia flexural fue valorada en base a las recomendaciones de la norma ISO 4049, mientras que el módulo elástico fue determinado según la norma Nº 27 (ANSI/ADA). Se encontraron diferencias significativas entre los diferentes materiales y procedimientos de curado empleados (P<0,01). El módulo elástico fue significativamente más elevado luego del procedimiento de curado adicional en todos los materiales,excepto en Premisa...


Subject(s)
Elastic Modulus , Polymerization/methods , Composite Resins/chemistry , Surface Properties , Tensile Strength , Light-Curing of Dental Adhesives , Materials Testing , Reference Standards , Data Interpretation, Statistical
20.
Rev. odontol. mex ; 18(1): 14-18, ene.-mar. 2014. ilus, tab
Article in Spanish | LILACS-Express | LILACS | ID: lil-714553

ABSTRACT

Se afirma en la literatura que el eugenol inhibe la polimerización de los cementos a base de resina; esto puede influir en la retención de los postes cementados con este material. Recientemente los postes prefabricados de resina, reforzados con fibras transparentes, fueron introducidos a la odontología con el propósito de que la luz para la fotopolimerización se transmita al medio cementante de resina a través de ellos, contribuyendo así a la reconstrucción estética y disminuyendo la incidencia de fracturas de dientes tratados endodóncicamente. Demostrando que empleando una técnica de grabado de ácido total por tiempos prolongados elimina los efectos del eugenol residual en los conductos radiculares sobre la retención de los postes translumínicos y la resina utilizada para cementar los mismos. Se realizaron tratamientos de conductos en 10 dientes extraídos, obturándose con puntas de gutapercha y cemento de óxido de zinc y eugenol, con la técnica de condensación lateral. Se prepararon los conductos con fresas de desobturación a baja velocidad, que se incluyen en el sistema de endopostes, y se cementaron con la técnica descrita por el fabricante, utilizando resina de cementación. Se les aplicó fuerza traccional hasta lograr su desalojo y se midió la retención. Resultados: La retención de cada una de las muestras fue graficada, demostrando que los valores de retención entre cada grupo no eran iguales; por lo que se estableció que no existe diferencia estadísticamente significativa. Conclusión: El eugenol residual no interfiere en la adhesión de postes cuando se emplea una técnica de grabado ácido en tiempos prolongados.


It has been reported in scientific literature, that eugenol inhibits polymerization of resin-based cements; this fact can influence retention of posts cemented upon this material. Recently, prefabricated resin posts reinforced with clear fibers have been introduced in the dental environment. The target of these new posts is twofold: the light used for polymerization can be transmitted to the resin cementing medium through the aforementioned posts, contributing thus to esthetic reconstruction and incidence decrease of endodontically treated teeth fractures. It has been shown that the use of a comprehensive acid-etch technique for extended time periods cancels residual eugenol effects in root canals on the light-transmitting posts and the resin used to cement them. In the present study 10 extracted teeth were subjected to root canal treatment. These teeth were sealed with gutta-percha points (cones) and zinc oxide-eugenol cement. For this endeavor, lateral condensation technique was used. Root canals were prepared with low speed burrs (as found in the endodontic-post system), to be then cemented with resin following the technique recommended by the manufacturer. Traction forces were applied until achieving dislodgement, at which point retention was assessed. Results: Retention of all samples was reflected into graphs. It could be appreciated that retention values among groups were unequal; it can therefore be established that no statistically significant difference was encountered. Conclusion: Residual eugenol did not interfere in post adhesion when an extended time acid etch technique was followed.

SELECTION OF CITATIONS
SEARCH DETAIL